Ultrasonic water meter

Helvatron H2O

For cold and hot water in residential, commercial and industrial buildings, for billing and for energy management to ISO 50001. Threaded from DN15 to DN40, flanged from DN50, all with ultrasonic measurement and an internal data logger.

Helvatron H2O ultrasonic water meter with threaded connection

Applications

Where is the H2O installed?

Wherever water volumes need to be measured reliably: in the distribution to flats and floors, at the service connection, in hot-water production and for process water.

  • Indoors, or outdoors in a pit or meter box; rated IP68
  • Any installation position: horizontal, vertical, rising or falling pipework
  • No straight inlet or outlet sections needed from DN15 to DN40
  • Records forward and reverse volume separately; detects leaks and air in the pipe
  • Nominal pressure PN16 or PN25, temperature classes T30 to T90

Typical projects

Water meters for flats: DN15 or DN20 with M-Bus, read by an M-Bus master in the plant room.

Service connection or zone: flanged from DN50, in a pit, read via LoRa with no cable to the metering point.

Industry and energy management: RS-485 and Modbus RTU, connected directly to the controller.

Measuring principle and data path

How does the H2O measure, and how do the values reach the control system?

Two ultrasonic transducers send pulses with and against the flow. Self-cleaning reflectors guide the sound through the measuring tube. The difference in transit time is a measure of the flow velocity. From this, the meter calculates the flow rate and volume and stores hourly, daily and monthly values in its own memory.

Service connectionDistributionShut-off valveInstallation gapLength L, e.g. 130 mm for DN20H2OM-BusUltrasonic Water MeterCEM27HELVATRONDN15–DN40: threaded, e.g. G 1 B for DN20from DN50: flangedArrow = flow direction · any installation positionWater flows through the measuring tubeMeasuring tube, sectional view (simplified)Transducer ATransducer Bt₁: A → B with the flow, shortert₂: B → A against the flow, longerTransit time difference t₂ − t₁ ∝ flow velocityFlow rate = velocity × cross-section2.47m³/hVolume is totalised · hourly, daily and monthly values storedEMU M-CenterM-Bus masterM-Bus · 2 wires · secondary addressdepending on version, also RS-485 (Modbus RTU) or LoRaBuilding managementWater today 3.2 m³MQTT · BACnet IP · Modbus TCP · CSV
  1. Prepare the pipeThe meter is fitted in the cold-water pipe between two shut-off valves. From DN15 to DN40, the H2O needs no straight inlet or outlet sections.
  2. Install the meterDN15 to DN40 with threaded connections, from DN50 with flanges. The arrow on the meter shows the flow direction; any installation position is permitted.
  3. Water flowsWater flows through the measuring tube of the meter to the distribution pipework in the building.
  4. Measure with ultrasoundTwo transducers alternately send pulses with and against the flow. The pulse travelling with the flow arrives sooner.
  5. Calculate flow rateThe transit time difference gives the flow velocity and hence the flow rate. The meter totalises the volume and stores hourly, daily and monthly values.
  6. Transmit dataAn M-Bus master such as the EMU M-Center reads the meter by its secondary address. Other versions transmit via RS-485 (Modbus RTU) or LoRa.
  7. Analyse in the control systemThe M-Center forwards the values via MQTT, BACnet IP, Modbus TCP or CSV to the building management and energy management systems.
Simplified illustration of the ultrasonic transit time principle. Values are examples. Install in accordance with the installation instructions.

More on the technology: Ultrasonic flow measurement · M-Bus

Connection types

Threaded up to DN40, flanged from DN50

Length and connection type depend on the nominal size. When selecting a meter, the flow rate matters, not just the pipe diameter.

H2OHELVATRON DN15 · 20 · 25 · 32 · 40

Threaded connection

G 3/4 B to G 2 B, lengths 110 to 300 mm. Q3 from 2.5 to 16 m³/h. Typical for flats, floors and smaller commercial units.

H2OHELVATRON DN50 to DN600

Flanged connection

Lengths 200 to 600 mm, Q3 from 25 to 4000 m³/h, dynamic range up to R800. For service connections, zones, distribution networks and industry.

Choose the nominal size

Which values apply to your nominal size?

Select a nominal size to see the connection, length, flow rates and the interfaces for which a part number is available.

Threaded connection
Flanged connection

Helvatron H2O DN15 Threaded connection

Connection
Thread G 3/4 B
Length
110 mm
Permanent flow rate Q3
2.5 m³/h
Overload flow rate Q4
3.125 m³/h
Minimum flow rate Q1
0.01 m³/h (R250) · 6.25 l/h (R400)
Ratio Q3/Q1
R250, R400, R500
Height
81 mm
Interfaces with part number
M-Bus WAAE.20C.ABM
RS-485 (Modbus RTU) WAAE.20C.ABMO
LoRa WAAE.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN20 Threaded connection

Connection
Thread G 1 B
Length
130 mm
Permanent flow rate Q3
4.0 m³/h
Overload flow rate Q4
5 m³/h
Minimum flow rate Q1
0.016 m³/h (R250) · 10 l/h (R400)
Ratio Q3/Q1
R250, R400, R500
Height
85 mm
Interfaces with part number
M-Bus WABG.20C.ABM
RS-485 (Modbus RTU) WABG.20C.ABMO
LoRa WABG.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN25 Threaded connection

Connection
Thread G 1 1/4 B
Length
260 mm
Permanent flow rate Q3
6.3 m³/h
Overload flow rate Q4
7.875 m³/h
Minimum flow rate Q1
0.025 m³/h (R250) · 15.75 l/h (R400)
Ratio Q3/Q1
R250, R400, R500
Height
129/130 mm
Interfaces with part number
M-Bus WACI.20C.ABM
RS-485 (Modbus RTU) WACI.20C.ABMO
LoRa WACI.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN32 Threaded connection

Connection
Thread G 1 1/2 B
Length
260 mm
Permanent flow rate Q3
10 m³/h
Overload flow rate Q4
12.5 m³/h
Minimum flow rate Q1
0.04 m³/h (R250) · 25 l/h (R400)
Ratio Q3/Q1
R250, R400, R500
Height
144 mm
Interfaces with part number
M-Bus WADJ.20C.ABM
RS-485 (Modbus RTU) WADJ.20C.ABMO
LoRa WADJ.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN40 Threaded connection

Connection
Thread G 2 B
Length
300 mm
Permanent flow rate Q3
16 m³/h
Overload flow rate Q4
20 m³/h
Minimum flow rate Q1
0.064 m³/h (R250) · 40 l/h (R400)
Ratio Q3/Q1
R250, R400, R500
Height
144/172 mm
Interfaces with part number
M-Bus WAEL.20C.ABM
RS-485 (Modbus RTU) WAEL.20C.ABMO
LoRa WAEL.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN50 Flanged connection

Connection
Flange DN50
Length
200 mm
Permanent flow rate Q3
25 m³/h
Overload flow rate Q4
31.25 m³/h
Minimum flow rate Q1
0.06 m³/h
Ratio Q3/Q1
R400, R800
Height
180/183 mm
Interfaces with part number
M-Bus WAFFM.20C.ABM
RS-485 (Modbus RTU) WAFFM.20C.ABMO
LoRa WAFFM.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN65 Flanged connection

Connection
Flange DN65
Length
200 mm
Permanent flow rate Q3
40 m³/h
Overload flow rate Q4
50 m³/h
Minimum flow rate Q1
0.125 m³/h
Ratio Q3/Q1
R400, R800
Height
197/200 mm
Interfaces with part number
M-Bus WAGFN.20C.ABM
RS-485 (Modbus RTU) WAGFN.20C.ABMO
LoRa WAGFN.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN80 Flanged connection

Connection
Flange DN80
Length
225 mm
Permanent flow rate Q3
63 m³/h
Overload flow rate Q4
78.25 m³/h
Minimum flow rate Q1
0.1575 m³/h
Ratio Q3/Q1
R400, R800
Height
222/235 mm
Interfaces with part number
M-Bus WAHFO.20C.ABM
RS-485 (Modbus RTU) WAHFO.20C.ABMO
LoRa WAHFO.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN100 Flanged connection

Connection
Flange DN100
Length
250 mm
Permanent flow rate Q3
100 m³/h
Overload flow rate Q4
125 m³/h
Minimum flow rate Q1
0.25 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAIFP.20C.ABM
RS-485 (Modbus RTU) WAIFP.20C.ABMO
LoRa WAIFP.20C.ABL
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN125 Flanged connection

Connection
Flange DN125
Length
250 mm
Permanent flow rate Q3
160 m³/h
Overload flow rate Q4
200 m³/h
Minimum flow rate Q1
0.4 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAJFQ.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN150 Flanged connection

Connection
Flange DN150
Length
300 mm
Permanent flow rate Q3
250 m³/h
Overload flow rate Q4
312.5 m³/h
Minimum flow rate Q1
0.625 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAKFS.20C.ABM
RS-485 (Modbus RTU) WAKFS.20C.ABMO
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN200 Flanged connection

Connection
Flange DN200
Length
350 mm
Permanent flow rate Q3
400 m³/h
Overload flow rate Q4
500 m³/h
Minimum flow rate Q1
1 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WALFU.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN250 Flanged connection

Connection
Flange DN250
Length
450 mm
Permanent flow rate Q3
630 m³/h
Overload flow rate Q4
787.5 m³/h
Minimum flow rate Q1
1.575 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAMFV.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN300 Flanged connection

Connection
Flange DN300
Length
500 mm
Permanent flow rate Q3
1000 m³/h
Overload flow rate Q4
1250 m³/h
Minimum flow rate Q1
2.5 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WANFZ.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN350 Flanged connection

Connection
Flange DN350
Length
500 mm
Permanent flow rate Q3
1000 m³/h
Overload flow rate Q4
1250 m³/h
Minimum flow rate Q1
2.5 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAOF0.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN400 Flanged connection

Connection
Flange DN400
Length
600 mm
Permanent flow rate Q3
1600 m³/h
Overload flow rate Q4
2000 m³/h
Minimum flow rate Q1
4 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAPF0.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN500 Flanged connection

Connection
Flange DN500
Length
600 mm
Permanent flow rate Q3
2500 m³/h
Overload flow rate Q4
3125 m³/h
Minimum flow rate Q1
6.25 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WARF0.20C.ABM
NB-IoT: in all nominal sizes

Request this nominal size

Helvatron H2O DN600 Flanged connection

Connection
Flange DN600
Length
600 mm
Permanent flow rate Q3
4000 m³/h
Overload flow rate Q4
5000 m³/h
Minimum flow rate Q1
10 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
No part number available; please enquire.
NB-IoT: in all nominal sizes

Request this nominal size

The current technical documentation is binding.

All nominal sizes as a table
Nominal sizeConnectionQ3Q4Q1L
DN15G 3/4 B2.53.1250.01110 mm
DN20G 1 B4.050.016130 mm
DN25G 1 1/4 B6.37.8750.025260 mm
DN32G 1 1/2 B1012.50.04260 mm
DN40G 2 B16200.064300 mm
DN50DN502531.250.06200 mm
DN65DN6540500.125200 mm
DN80DN806378.250.1575225 mm
DN100DN1001001250.25250 mm
DN125DN1251602000.4250 mm
DN150DN150250312.50.625300 mm
DN200DN2004005001350 mm
DN250DN250630787.51.575450 mm
DN300DN300100012502.5500 mm
DN350DN350100012502.5500 mm
DN400DN400160020004600 mm
DN500DN500250031256.25600 mm
DN600DN6004000500010600 mm

Q3, Q4, Q1 in m³/h. The current technical documentation is binding.

Help with sizing: Choosing the right nominal size

Interfaces and data

How is the H2O read?

You specify the interface via the part number. The optical D0 interface is always available for on-site configuration and reading.

M-Bus (wired)
Bus and protocol in one. The meter can optionally be powered via the M-Bus. More
Wireless M-Bus
Radio telegrams in S1, T1 and OMS mode.
RS-485 · Modbus RTU
RS-485 as the physical interface, Modbus RTU as the protocol. More
LoRa, 868 MHz
Radio to LoRa gateways. More
NB-IoT
Via the mobile network in all nominal sizes, without a radio network of your own. More

Values provided by the H2O

  • Total volume
  • Forward volume
  • Reverse volume
  • Volume of pulse inputs 1 and 2
  • Maximum and minimum flow rate with date
  • Maximum and minimum temperature with date (if used)
  • Error-free operating time
  • Error code
  • Time above 1.2 × Q4 and below Q1

Alarms

  • Low battery
  • Air in pipe
  • Leak detection

The serial number is also printed as a QR code on the meter. This makes it quick to set up the meter in energy management systems such as Joulio-Web.

Technical data

Helvatron H2O at a glance

Nominal sizes
DN15–DN600 · Threaded DN15–DN40, flanged from DN50
Approvals and standards
MID (class 2) · MID module D, METAS-Cert · CE · WRAS · OIML R 49 · EN 14154 · ISO 4064
Accuracy
Class 2 (OIML R 49)
Dynamic range
Q3/Q1 R250, R400 or R500 (DN15–DN40); flanged versions R400 or R800
Temperature classes
T30, T50, T70, T90
Medium temperature
Standard 0.1 °C to 50 °C; on request 1 °C to 70 °C or 90 °C
Ambient temperature
+5 °C … +65 °C
Nominal pressure
PN16 / PN25
Ingress protection
IP68
Installation location
indoors, or outdoors in a pit or meter box
Installation position
any position: horizontal, vertical, rising or falling pipe
Straight inlet/outlet sections
DN15–DN40: no straight inlet or outlet sections required; larger sizes as per the installation instructions
Wetted parts
Lead-free brass or stainless steel (wetted parts)
Display
8-digit LCD
Power supply
3.6 V battery, battery life 10 to 16 years. Option: external supply 12…42 V DC or power via M-Bus
Interfaces
M-Bus · Wireless M-Bus (S1, T1, OMS) · RS-485 (Modbus RTU) · LoRa 868 MHz · NB-IoT · Optical interface D0

The current technical documentation is binding.

Part numbers

Part numbers by nominal size and interface

Shown for temperature class T50 (code letter C). For T70, replace it with H, for example WABG.20H.ABM. T90 on request.

Nominal sizeM-BusRS-485 (Modbus RTU)LoRa
DN15WAAE.20C.ABMWAAE.20C.ABMOWAAE.20C.ABL
DN20WABG.20C.ABMWABG.20C.ABMOWABG.20C.ABL
DN25WACI.20C.ABMWACI.20C.ABMOWACI.20C.ABL
DN32WADJ.20C.ABMWADJ.20C.ABMOWADJ.20C.ABL
DN40WAEL.20C.ABMWAEL.20C.ABMOWAEL.20C.ABL
DN50WAFFM.20C.ABMWAFFM.20C.ABMOWAFFM.20C.ABL
DN65WAGFN.20C.ABMWAGFN.20C.ABMOWAGFN.20C.ABL
DN80WAHFO.20C.ABMWAHFO.20C.ABMOWAHFO.20C.ABL
DN100WAIFP.20C.ABMWAIFP.20C.ABMOWAIFP.20C.ABL
DN125WAJFQ.20C.ABMNo part number with this interface.No part number with this interface.
DN150WAKFS.20C.ABMWAKFS.20C.ABMONo part number with this interface.
DN200WALFU.20C.ABMNo part number with this interface.No part number with this interface.
DN250WAMFV.20C.ABMNo part number with this interface.No part number with this interface.
DN300WANFZ.20C.ABMNo part number with this interface.No part number with this interface.
DN350WAOF0.20C.ABMNo part number with this interface.No part number with this interface.
DN400WAPF0.20C.ABMNo part number with this interface.No part number with this interface.
DN500WARF0.20C.ABMNo part number with this interface.No part number with this interface.

NB-IoT is available in all nominal sizes. Wireless M-Bus and sizes not listed in this table are available on request.

Questions

Frequently asked questions about the H2O

Does the H2O need straight inlet and outlet sections?

Not from DN15 to DN40. For larger sizes, the installation instructions apply. The meter can be installed in any position.

Which nominal sizes are threaded and which are flanged?

DN15, DN20, DN25, DN32 and DN40 have threaded connections from G 3/4 B to G 2 B. From DN50 to DN600, the H2O is flanged.

Can the H2O measure hot water?

Yes. The standard medium temperature range is 0.1 to 50 °C (T50). Versions up to 70 °C or 90 °C are available on request.

How long does the battery last?

The 3.6 V battery lasts 10 to 16 years, depending on interface and reading interval. Alternatively, it can be powered by an external 12 to 42 V DC supply or via the M-Bus.

Which approvals does the H2O have?

MID class 2 with CE marking, production certified to MID module D by METAS-Cert, and WRAS approval. It complies with OIML R 49, EN 14154 and ISO 4064.

Is the H2O available with NB-IoT?

Yes, in all nominal sizes. The meter then transmits over the mobile network, with no bus cable and no gateway of your own.

Does the meter detect reverse flow?

Yes. It records forward and reverse volume separately and also reports leaks and air in the pipe.

A project with the H2O?

Tell us the nominal sizes, quantity and interface, and we will send you the data sheet, part numbers and a quotation.