Key terms relating to water meters, heat meters, ultrasound and temperature difference, briefly explained and, where possible, with values for the H2O and DELTA III.
No matching terms found.
Water meters
- Q3 – permanent flow rate
- The flow rate at which a water meter may be operated continuously. For the H2O from 2.5 m³/h (DN15) to 4000 m³/h (DN600).
- Q4 – overload flow rate
- Highest flow rate permitted for short periods. For the H2O, 1.25 times Q3.
- Q1 – minimum flow rate
- Lowest flow rate at which the meter measures within the maximum permissible errors.
- Dynamic range R
- Ratio Q3/Q1, for heat meters qp/qi. R400 means the meter measures accurately down to one four-hundredth of the permanent flow rate.
- Temperature class
- Upper limit of the water temperature, for example T50 for 50 °C. The H2O is available with T30, T50, T70 and T90.
- Reverse flow
- Water flowing against the direction of the arrow. The H2O records forward and reverse volume separately.
- Straight inlet and outlet sections
- Straight pipe upstream and downstream of a meter that allows the flow profile to settle. The H2O and DELTA III need none from DN15 to DN40.
- WRAS
- UK approval for products in contact with drinking water. The H2O is WRAS-approved.
Heat meters and temperature
- Heat meter
- Measuring instrument for thermal energy, consisting of a flow sensor, a temperature sensor pair and a calculator.
- Cooling meter
- Measures cooling energy; the return is warmer than the flow. The DELTA III counts heating and cooling in separate registers.
- BTU meter
- Term for heat and cooling meters common in the Middle East and North America. BTU stands for British Thermal Unit.
- Flow
- Pipe from the heating or cooling source to the consumer.
- Return
- Pipe from the consumer back to the source.
- Temperature difference Δθ
- Difference between flow and return temperature in kelvin. The smaller the Δθ, the more accurate the sensors need to be.
- Kelvin (K)
- Unit for temperature differences. 1 K equals a difference of 1 °C.
- Heat coefficient k
- Factor accounting for the density and specific heat capacity of water, which depend on temperature. Defined in EN 1434.
- Calculator
- The heat meter’s electronics, which calculate the energy from volume and temperatures, display it and store it.
- Pt500 / Pt1000
- Platinum resistance sensors with 500 Ω or 1000 Ω at 0 °C. Pt1000 is less sensitive to the resistance of the connecting cable.
- Temperature sensor pair
- The two matched temperature sensors of a heat meter.
- Split type
- Calculator mounted separately from the flow sensor, connected by a cable.
- qp – nominal flow rate
- Continuous flow rate of a heat meter. For the DELTA III from 1.5 m³/h (DN15) to 6000 m³/h (DN1000).
- qi / qs
- Lowest and highest permitted flow rate of a heat meter. For the DELTA III, qs = 2 × qp.
Ultrasound
- Ultrasonic transducer
- Component that converts electrical pulses into sound and vice versa. Two transducers alternately send and receive.
- Transit time method
- Measuring principle that compares the transit time of a sound pulse with and against the flow. The difference is proportional to the flow velocity.
- Reflector
- Mirror in the measuring tube that guides the sound along a defined path. Metallic and self-cleaning in the DELTA III.
- Measuring channel
- One sound path through the pipe. The DELTA III measures with 2 channels from DN50 and 4 from DN350.
- Air in pipe
- Air bubbles disturb sound propagation. Ultrasonic meters detect this and report an error.
- Flushing
- Flushing new pipework before the meter is fitted, to remove dirt and installation debris. Until then, a spool piece is fitted in place of the meter.
Standards and approvals
- MID
- European Measuring Instruments Directive 2014/32/EU. A prerequisite for meters used for billing.
- Module B and module D
- Conformity assessment procedures under the MID: B is the type examination, D the quality assurance of production.
- EN 1434
- European standard for heat meters.
- EN 14154 / ISO 4064
- Standards for water meters.
- OIML R 49
- International recommendation for water meters, the basis of many national regulations.
- IP68 / IP65
- Degrees of protection against dust and water. IP68: continuous immersion.
Communication
- M-Bus
- Meter-Bus to EN 13757: two-wire bus on which one master reads many meters.
- Secondary address
- Unique M-Bus address assigned to a meter at the factory.
- Wireless M-Bus
- Radio version of M-Bus; for the H2O in S1, T1 and OMS modes.
- RS-485
- Electrical interface for differential data transmission over a twisted pair.
- Modbus RTU
- Master-slave protocol that runs over RS-485.
- LoRa
- Radio network protocol for low-power devices; in Europe it uses the 868 MHz band.
- OTAA
- Over-the-air activation: a LoRa device joins the network with newly derived session keys.
- NB-IoT
- Mobile network standard for small amounts of data.
- Optical interface D0
- Infrared interface on the front of the meter for on-site configuration and reading.