Ultrasonic water meter

Helvatron H2O

For cold and hot water in residential, commercial and industrial buildings, for billing and for energy management to ISO 50001. Threaded from DN15 to DN40, flanged from DN50, all with ultrasonic measurement and an internal data logger.

Helvatron H2O ultrasonic water meter with threaded connection

Applications

Where is the H2O installed?

Wherever water volumes need to be measured reliably: in the distribution to flats and floors, at the service connection, in hot-water production and for process water. The H2O can be installed indoors, outdoors in a pit or in a meter box (IP68), horizontally or vertically in rising pipework. From DN15 to DN40 it needs no straight inlet or outlet sections.

  • Indoors, or outdoors in a pit or meter box; rated IP68
  • Horizontal or vertical installation, vertical only in rising pipework
  • No straight inlet or outlet sections needed from DN15 to DN40
  • Records forward and reverse volume separately; detects leaks and air in the pipe
  • Nominal pressure PN16 or PN25, temperature classes T30 to T90

Typical projects

Water meters for flats: DN15 or DN20 with M-Bus, read by an M-Bus master in the plant room.

Service connection or zone: flanged from DN50, in a pit, read via LoRa with no cable to the metering point.

Industry and energy management: RS-485 and Modbus RTU, connected directly to the controller.

Measuring principle and data path

How does the H2O measure, and how do the values reach the control system?

Two ultrasonic transducers send pulses with and against the flow. Self-cleaning reflectors guide the sound through the measuring tube. The difference in transit time is a measure of the flow velocity. From this, the meter calculates the flow rate and volume and stores hourly, daily and monthly values in its own memory.

Service connectionDistributionShut-off valveInstallation gapLength L, e.g. 130 mm for DN20H2OM-BusUltrasonic Water MeterCEM27HELVATRONDN15–DN40: threaded, e.g. G 1 B for DN20from DN50: flangedArrow = flow direction · horizontal or vertically risingWater flows through the measuring tubeMeasuring tube, sectional view (simplified)Transducer ATransducer Bt₁: A → B with the flow, shortert₂: B → A against the flow, longerTransit time difference t₂ − t₁ ∝ flow velocityFlow rate = velocity × cross-section2.47m³/hVolume is totalised · hourly, daily and monthly values storedEMU M-CenterM-Bus masterM-Bus · 2 wires · secondary addressdepending on version, also RS-485 (Modbus RTU) or LoRaBuilding managementWater today 3.2 m³MQTT · BACnet IP · Modbus TCP · CSV
  1. Prepare the pipeThe meter is fitted in the cold-water pipe between two shut-off valves. From DN15 to DN40, the H2O needs no straight inlet or outlet sections.
  2. Install the meterDN15 to DN40 with threaded connections, from DN50 with flanges. The arrow on the meter shows the flow direction. Install horizontally or vertically in a rising pipe.
  3. Water flowsWater flows through the measuring tube of the meter to the distribution pipework in the building.
  4. Measure with ultrasoundTwo transducers alternately send pulses with and against the flow. The pulse travelling with the flow arrives sooner.
  5. Calculate flow rateThe transit time difference gives the flow velocity and hence the flow rate. The meter totalises the volume and stores hourly, daily and monthly values.
  6. Transmit dataAn M-Bus master such as the EMU M-Center reads the meter by its secondary address. Other versions transmit via RS-485 (Modbus RTU) or LoRa.
  7. Analyse in the control systemThe M-Center forwards the values via MQTT, BACnet IP, Modbus TCP or CSV to the building management and energy management systems.
Simplified illustration of the ultrasonic transit time principle. Values are examples. Install in accordance with the installation instructions.

More on the technology: Ultrasonic flow measurement · M-Bus

Connection types

Threaded up to DN40, flanged from DN50

Length and connection type depend on the nominal size. When selecting a meter, the flow rate matters, not just the pipe diameter.

H2OHELVATRON DN15 · 20 · 25 · 32 · 40

Threaded connection

G 3/4 B to G 2 B, lengths 110 to 300 mm. Q3 from 2.5 to 16 m³/h. Typical for flats, floors and smaller commercial units.

H2OHELVATRON DN50 to DN600

Flanged connection

Lengths 200 to 600 mm, Q3 from 25 to 4000 m³/h, dynamic range up to R800. For service connections, zones, distribution networks and industry.

Choose the nominal size

Which values apply to your nominal size?

Select a nominal size to see the connection, length, flow rates and the interfaces for which a part number is available.

Threaded connection
Flanged connection

Helvatron H2O DN15 Threaded connection

Connection
Thread G 3/4 B
Length
110 mm
Permanent flow rate Q3
2.5 m³/h
Overload flow rate Q4
3.125 m³/h
Minimum flow rate Q1
0.01 m³/h (R250) · 6.25 l/h (R400)
Ratio Q3/Q1
R250, R400, R500, R800
Height
81 mm
Interfaces with part number
M-Bus WAAE.20C.ABM
RS-485 (Modbus RTU) WAAE.20C.ABMO
LoRa WAAE.20C.ABL
Wireless M-Bus 868 MHz WAAE.20C.ABWM8
Wireless M-Bus 434 MHz WAAE.20C.ABWM4
NB-IoT WAAE.20C.ABN

Request this nominal size

Helvatron H2O DN20 Threaded connection

Connection
Thread G 1 B
Length
130 mm
Permanent flow rate Q3
4.0 m³/h
Overload flow rate Q4
5 m³/h
Minimum flow rate Q1
0.016 m³/h (R250) · 10 l/h (R400)
Ratio Q3/Q1
R250, R400, R500, R800
Height
85 mm
Interfaces with part number
M-Bus WABG.20C.ABM
RS-485 (Modbus RTU) WABG.20C.ABMO
LoRa WABG.20C.ABL
Wireless M-Bus 868 MHz WABG.20C.ABWM8
Wireless M-Bus 434 MHz WABG.20C.ABWM4
NB-IoT WABG.20C.ABN

Request this nominal size

Helvatron H2O DN25 Threaded connection

Connection
Thread G 1 1/4 B
Length
260 mm
Permanent flow rate Q3
6.3 m³/h
Overload flow rate Q4
7.875 m³/h
Minimum flow rate Q1
0.025 m³/h (R250) · 15.75 l/h (R400)
Ratio Q3/Q1
R250, R400, R500, R800
Height
129/130 mm
Interfaces with part number
M-Bus WACI.20C.ABM
RS-485 (Modbus RTU) WACI.20C.ABMO
LoRa WACI.20C.ABL
Wireless M-Bus 868 MHz WACI.20C.ABWM8
Wireless M-Bus 434 MHz WACI.20C.ABWM4
NB-IoT WACI.20C.ABN

Request this nominal size

Helvatron H2O DN32 Threaded connection

Connection
Thread G 1 1/2 B
Length
260 mm
Permanent flow rate Q3
10 m³/h
Overload flow rate Q4
12.5 m³/h
Minimum flow rate Q1
0.04 m³/h (R250) · 25 l/h (R400)
Ratio Q3/Q1
R250, R400, R500, R800
Height
144 mm
Interfaces with part number
M-Bus WADJ.20C.ABM
RS-485 (Modbus RTU) WADJ.20C.ABMO
LoRa WADJ.20C.ABL
Wireless M-Bus 868 MHz WADJ.20C.ABWM8
Wireless M-Bus 434 MHz WADJ.20C.ABWM4
NB-IoT WADJ.20C.ABN

Request this nominal size

Helvatron H2O DN40 Threaded connection

Connection
Thread G 2 B
Length
300 mm
Permanent flow rate Q3
16 m³/h
Overload flow rate Q4
20 m³/h
Minimum flow rate Q1
0.064 m³/h (R250) · 40 l/h (R400)
Ratio Q3/Q1
R250, R400, R500, R800
Height
144/172 mm
Interfaces with part number
M-Bus WAEL.20C.ABM
RS-485 (Modbus RTU) WAEL.20C.ABMO
LoRa WAEL.20C.ABL
Wireless M-Bus 868 MHz WAEL.20C.ABWM8
Wireless M-Bus 434 MHz WAEL.20C.ABWM4
NB-IoT WAEL.20C.ABN

Request this nominal size

Helvatron H2O DN50 Flanged connection

Connection
Flange DN50
Length
200 mm
Permanent flow rate Q3
25 m³/h
Overload flow rate Q4
31.25 m³/h
Minimum flow rate Q1
0.06 m³/h
Ratio Q3/Q1
R400, R800
Height
180/183 mm
Interfaces with part number
M-Bus WAFFM.20C.ABM
RS-485 (Modbus RTU) WAFFM.20C.ABMO
LoRa WAFFM.20C.ABL
Wireless M-Bus 868 MHz WAFFM.20C.ABWM8
Wireless M-Bus 434 MHz WAFFM.20C.ABWM4
NB-IoT WAFFM.20C.ABN

Request this nominal size

Helvatron H2O DN65 Flanged connection

Connection
Flange DN65
Length
200 mm
Permanent flow rate Q3
40 m³/h
Overload flow rate Q4
50 m³/h
Minimum flow rate Q1
0.125 m³/h
Ratio Q3/Q1
R400, R800
Height
197/200 mm
Interfaces with part number
M-Bus WAGFN.20C.ABM
RS-485 (Modbus RTU) WAGFN.20C.ABMO
LoRa WAGFN.20C.ABL
Wireless M-Bus 868 MHz WAGFN.20C.ABWM8
Wireless M-Bus 434 MHz WAGFN.20C.ABWM4
NB-IoT WAGFN.20C.ABN

Request this nominal size

Helvatron H2O DN80 Flanged connection

Connection
Flange DN80
Length
225 mm
Permanent flow rate Q3
63 m³/h
Overload flow rate Q4
78.25 m³/h
Minimum flow rate Q1
0.1575 m³/h
Ratio Q3/Q1
R400, R800
Height
222/235 mm
Interfaces with part number
M-Bus WAHFO.20C.ABM
RS-485 (Modbus RTU) WAHFO.20C.ABMO
LoRa WAHFO.20C.ABL
Wireless M-Bus 868 MHz WAHFO.20C.ABWM8
Wireless M-Bus 434 MHz WAHFO.20C.ABWM4
NB-IoT WAHFO.20C.ABN

Request this nominal size

Helvatron H2O DN100 Flanged connection

Connection
Flange DN100
Length
250 mm
Permanent flow rate Q3
100 m³/h
Overload flow rate Q4
125 m³/h
Minimum flow rate Q1
0.25 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAIFP.20C.ABM
RS-485 (Modbus RTU) WAIFP.20C.ABMO
LoRa WAIFP.20C.ABL
Wireless M-Bus 868 MHz WAIFP.20C.ABWM8
Wireless M-Bus 434 MHz WAIFP.20C.ABWM4
NB-IoT WAIFP.20C.ABN

Request this nominal size

Helvatron H2O DN125 Flanged connection

Connection
Flange DN125
Length
250 mm
Permanent flow rate Q3
160 m³/h
Overload flow rate Q4
200 m³/h
Minimum flow rate Q1
0.4 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAJFQ.20C.ABM
RS-485 (Modbus RTU) WAJFQ.20C.ABMO
LoRa WAJFQ.20C.ABL
Wireless M-Bus 868 MHz WAJFQ.20C.ABWM8
Wireless M-Bus 434 MHz WAJFQ.20C.ABWM4
NB-IoT WAJFQ.20C.ABN

Request this nominal size

Helvatron H2O DN150 Flanged connection

Connection
Flange DN150
Length
300 mm
Permanent flow rate Q3
250 m³/h
Overload flow rate Q4
312.5 m³/h
Minimum flow rate Q1
0.625 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAKFS.20C.ABM
RS-485 (Modbus RTU) WAKFS.20C.ABMO
LoRa WAKFS.20C.ABL
Wireless M-Bus 868 MHz WAKFS.20C.ABWM8
Wireless M-Bus 434 MHz WAKFS.20C.ABWM4
NB-IoT WAKFS.20C.ABN

Request this nominal size

Helvatron H2O DN200 Flanged connection

Connection
Flange DN200
Length
350 mm
Permanent flow rate Q3
400 m³/h
Overload flow rate Q4
500 m³/h
Minimum flow rate Q1
1 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WALFU.20C.ABM
RS-485 (Modbus RTU) WALFU.20C.ABMO
LoRa WALFU.20C.ABL
Wireless M-Bus 868 MHz WALFU.20C.ABWM8
Wireless M-Bus 434 MHz WALFU.20C.ABWM4
NB-IoT WALFU.20C.ABN

Request this nominal size

Helvatron H2O DN250 Flanged connection

Connection
Flange DN250
Length
450 mm
Permanent flow rate Q3
630 m³/h
Overload flow rate Q4
787.5 m³/h
Minimum flow rate Q1
1.575 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAMFV.20C.ABM
RS-485 (Modbus RTU) WAMFV.20C.ABMO
LoRa WAMFV.20C.ABL
Wireless M-Bus 868 MHz WAMFV.20C.ABWM8
Wireless M-Bus 434 MHz WAMFV.20C.ABWM4
NB-IoT WAMFV.20C.ABN

Request this nominal size

Helvatron H2O DN300 Flanged connection

Connection
Flange DN300
Length
500 mm
Permanent flow rate Q3
1000 m³/h
Overload flow rate Q4
1250 m³/h
Minimum flow rate Q1
2.5 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WANFZ.20C.ABM
RS-485 (Modbus RTU) WANFZ.20C.ABMO
LoRa WANFZ.20C.ABL
Wireless M-Bus 868 MHz WANFZ.20C.ABWM8
Wireless M-Bus 434 MHz WANFZ.20C.ABWM4
NB-IoT WANFZ.20C.ABN

Request this nominal size

Helvatron H2O DN350 Flanged connection

Connection
Flange DN350
Length
500 mm
Permanent flow rate Q3
1000 m³/h
Overload flow rate Q4
1250 m³/h
Minimum flow rate Q1
2.5 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAOF0.20C.ABM
RS-485 (Modbus RTU) WAOF0.20C.ABMO
LoRa WAOF0.20C.ABL
Wireless M-Bus 868 MHz WAOF0.20C.ABWM8
Wireless M-Bus 434 MHz WAOF0.20C.ABWM4
NB-IoT WAOF0.20C.ABN

Request this nominal size

Helvatron H2O DN400 Flanged connection

Connection
Flange DN400
Length
600 mm
Permanent flow rate Q3
1600 m³/h
Overload flow rate Q4
2000 m³/h
Minimum flow rate Q1
4 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WAPF0.20C.ABM
RS-485 (Modbus RTU) WAPF0.20C.ABMO
LoRa WAPF0.20C.ABL
Wireless M-Bus 868 MHz WAPF0.20C.ABWM8
Wireless M-Bus 434 MHz WAPF0.20C.ABWM4
NB-IoT WAPF0.20C.ABN

Request this nominal size

Helvatron H2O DN500 Flanged connection

Connection
Flange DN500
Length
600 mm
Permanent flow rate Q3
2500 m³/h
Overload flow rate Q4
3125 m³/h
Minimum flow rate Q1
6.25 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
M-Bus WARF0.20C.ABM
RS-485 (Modbus RTU) WARF0.20C.ABMO
LoRa WARF0.20C.ABL
Wireless M-Bus 868 MHz WARF0.20C.ABWM8
Wireless M-Bus 434 MHz WARF0.20C.ABWM4
NB-IoT WARF0.20C.ABN

Request this nominal size

Helvatron H2O DN600 Flanged connection

Connection
Flange DN600
Length
600 mm
Permanent flow rate Q3
4000 m³/h
Overload flow rate Q4
5000 m³/h
Minimum flow rate Q1
10 m³/h
Ratio Q3/Q1
R400, R800
Interfaces with part number
No part number available; please enquire.

Request this nominal size

The current technical documentation is binding.

All nominal sizes as a table
Nominal sizeConnectionQ3Q4Q1L
DN15G 3/4 B2.53.1250.01110 mm
DN20G 1 B4.050.016130 mm
DN25G 1 1/4 B6.37.8750.025260 mm
DN32G 1 1/2 B1012.50.04260 mm
DN40G 2 B16200.064300 mm
DN50DN502531.250.06200 mm
DN65DN6540500.125200 mm
DN80DN806378.250.1575225 mm
DN100DN1001001250.25250 mm
DN125DN1251602000.4250 mm
DN150DN150250312.50.625300 mm
DN200DN2004005001350 mm
DN250DN250630787.51.575450 mm
DN300DN300100012502.5500 mm
DN350DN350100012502.5500 mm
DN400DN400160020004600 mm
DN500DN500250031256.25600 mm
DN600DN6004000500010600 mm

Q3, Q4, Q1 in m³/h. The current technical documentation is binding.

Help with sizing: Choosing the right nominal size

Interfaces and data

How is the H2O read?

You specify the interface via the part number: M-Bus, RS-485 with Modbus RTU, LoRa, Wireless M-Bus at 868 or 434 MHz, or NB-IoT. In addition, the meter can always be configured and read on site via the optical D0 interface. The serial number is also printed on the meter as a QR code.

M-Bus (wired)
Bus and protocol in one. More
Wireless M-Bus, 868 / 434 MHz
Radio telegrams in S1, T1 and OMS mode.
RS-485 · Modbus RTU
RS-485 as the physical interface, Modbus RTU as the protocol. More
LoRa, 868 MHz
Radio to LoRa gateways. More
NB-IoT
Via the mobile network in all nominal sizes, without a radio network of your own. More

Values provided by the H2O

  • Total volume
  • Forward volume
  • Reverse volume
  • Volume of pulse inputs 1 and 2
  • Maximum and minimum flow rate with date
  • Maximum and minimum temperature with date (if used)
  • Error-free operating time
  • Error code
  • Time above 1.2 × Q4 and below Q1

Alarms

  • Low battery
  • Air in pipe
  • Leak detection

The serial number is also printed as a QR code on the meter. This makes it quick to set up the meter in energy management systems such as Joulio-Web.

Technical data

Helvatron H2O at a glance

Nominal sizes
DN15–DN600 · Threaded DN15–DN40, flanged from DN50
Approvals and standards
MID (class 2) · MID module D, METAS-Cert · CE · WRAS · OIML R 49 · EN 14154 · ISO 4064
Accuracy
Class 2 (OIML R 49)
Dynamic range
Q3/Q1 R250, R400, R500 or R800 (DN15–DN40); flanged versions R400 or R800
Temperature classes
T30, T50, T70, T90
Medium temperature
Standard 0.1 °C to 50 °C; on request 1 °C to 70 °C or 90 °C
Ambient temperature
+5 °C … +65 °C
Nominal pressure
PN16 / PN25
Ingress protection
IP68
Installation location
indoors, or outdoors in a pit or meter box
Installation position
horizontal or vertical; vertical only in a rising pipe (flow from bottom to top)
Straight inlet/outlet sections
DN15–DN40: no straight inlet or outlet sections required; larger sizes as per the installation instructions
Wetted parts
Lead-free brass or stainless steel (wetted parts)
Display
8-digit LCD
Power supply
3.6 V battery, battery life 10 to 16 years. Option: external supply 12…42 V DC
Interfaces
M-Bus · Wireless M-Bus 868 MHz (S1, T1, OMS) / 434 MHz · RS-485 (Modbus RTU) · LoRa 868 MHz · NB-IoT · Optical interface D0

The current technical documentation is binding.

Part numbers

Part numbers by nominal size and interface

Shown for temperature class T50 (code letter C). For T70, replace it with H, for example WABG.20H.ABM. T90 on request.

Nominal sizeM-BusRS-485 (Modbus RTU)LoRaWireless M-Bus 868 MHzWireless M-Bus 434 MHzNB-IoT
DN15WAAE.20C.ABMWAAE.20C.ABMOWAAE.20C.ABLWAAE.20C.ABWM8WAAE.20C.ABWM4WAAE.20C.ABN
DN20WABG.20C.ABMWABG.20C.ABMOWABG.20C.ABLWABG.20C.ABWM8WABG.20C.ABWM4WABG.20C.ABN
DN25WACI.20C.ABMWACI.20C.ABMOWACI.20C.ABLWACI.20C.ABWM8WACI.20C.ABWM4WACI.20C.ABN
DN32WADJ.20C.ABMWADJ.20C.ABMOWADJ.20C.ABLWADJ.20C.ABWM8WADJ.20C.ABWM4WADJ.20C.ABN
DN40WAEL.20C.ABMWAEL.20C.ABMOWAEL.20C.ABLWAEL.20C.ABWM8WAEL.20C.ABWM4WAEL.20C.ABN
DN50WAFFM.20C.ABMWAFFM.20C.ABMOWAFFM.20C.ABLWAFFM.20C.ABWM8WAFFM.20C.ABWM4WAFFM.20C.ABN
DN65WAGFN.20C.ABMWAGFN.20C.ABMOWAGFN.20C.ABLWAGFN.20C.ABWM8WAGFN.20C.ABWM4WAGFN.20C.ABN
DN80WAHFO.20C.ABMWAHFO.20C.ABMOWAHFO.20C.ABLWAHFO.20C.ABWM8WAHFO.20C.ABWM4WAHFO.20C.ABN
DN100WAIFP.20C.ABMWAIFP.20C.ABMOWAIFP.20C.ABLWAIFP.20C.ABWM8WAIFP.20C.ABWM4WAIFP.20C.ABN
DN125WAJFQ.20C.ABMWAJFQ.20C.ABMOWAJFQ.20C.ABLWAJFQ.20C.ABWM8WAJFQ.20C.ABWM4WAJFQ.20C.ABN
DN150WAKFS.20C.ABMWAKFS.20C.ABMOWAKFS.20C.ABLWAKFS.20C.ABWM8WAKFS.20C.ABWM4WAKFS.20C.ABN
DN200WALFU.20C.ABMWALFU.20C.ABMOWALFU.20C.ABLWALFU.20C.ABWM8WALFU.20C.ABWM4WALFU.20C.ABN
DN250WAMFV.20C.ABMWAMFV.20C.ABMOWAMFV.20C.ABLWAMFV.20C.ABWM8WAMFV.20C.ABWM4WAMFV.20C.ABN
DN300WANFZ.20C.ABMWANFZ.20C.ABMOWANFZ.20C.ABLWANFZ.20C.ABWM8WANFZ.20C.ABWM4WANFZ.20C.ABN
DN350WAOF0.20C.ABMWAOF0.20C.ABMOWAOF0.20C.ABLWAOF0.20C.ABWM8WAOF0.20C.ABWM4WAOF0.20C.ABN
DN400WAPF0.20C.ABMWAPF0.20C.ABMOWAPF0.20C.ABLWAPF0.20C.ABWM8WAPF0.20C.ABWM4WAPF0.20C.ABN
DN500WARF0.20C.ABMWARF0.20C.ABMOWARF0.20C.ABLWARF0.20C.ABWM8WARF0.20C.ABWM4WARF0.20C.ABN

Questions

Frequently asked questions about the H2O

Does the H2O need straight inlet and outlet sections?

Not from DN15 to DN40. For larger sizes, the installation instructions apply. The meter can be installed horizontally or vertically, vertically only in a rising pipe.

Which nominal sizes are threaded and which are flanged?

DN15, DN20, DN25, DN32 and DN40 have threaded connections from G 3/4 B to G 2 B. From DN50 to DN600, the H2O is flanged.

Can the H2O measure hot water?

Yes. The standard medium temperature range is 0.1 to 50 °C (T50). Versions up to 70 °C or 90 °C are available on request.

How long does the battery last?

The 3.6 V battery lasts 10 to 16 years, depending on interface and reading interval. Alternatively, it can be powered by an external 12 to 42 V DC supply.

Which approvals does the H2O have?

MID class 2 with CE marking, production certified to MID module D by METAS-Cert, and WRAS approval. It complies with OIML R 49, EN 14154 and ISO 4064.

Is the H2O available with NB-IoT?

Yes, in all nominal sizes. The meter then transmits over the mobile network, with no bus cable and no gateway of your own.

Does the meter detect reverse flow?

Yes. It records forward and reverse volume separately and also reports leaks and air in the pipe.

A project with the H2O?

Tell us the nominal sizes, quantity and interface, and we will send you the data sheet, part numbers and a quotation.